FJK6623PB

Material of filter pad: 100g/ M3 nylon fiber compound, Filtration efficiency up to 7 3%.

Operation Temperature/Humidity Range: (under unconcretionary state) -20℃ ~ +70℃ (temperature), 0% ~ 95% (himidity)

RAL 7035 grey is the standard offer with the possibility to change to RAL 7032 by means of a replacement grille.

Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate.

Protection class: E N 60 5 29 I P 5 4 (not suitable for outdoor equipment).

Ventilation Systems Fan Filter FJK6623PB

Technical Parameter

References are based on the frame dimension, which helps you to quickly select the best choice for your installation.

Example:
When your installation space is enough for dimention 120*120*38mm, please choose FJ1203

When you choose AC 220V, frame size 120x120x38mm, sleeve bearing, plug-in connection, please choose model FJ12032AST

We can customize your unconventional products.


Characteristics:

It comprises of a cooling fan, a protective housing on the front and rear surfaces and filter designed to retain dust particles.

The filters that equip the fans must be cleaned and replaced regularly.

It can produce all kinds of flame retardant V0 grade material and filter panel.

Material of filter pad: 100g/ M3 nylon fiber compound, Filtration efficiency up to 7 3%.

Operation Temperature/Humidity Range: (under unconcretionary state) -20℃ ~ +70℃ (temperature), 0% ~ 95% (himidity)

RAL 7035 grey is the standard offer with the possibility to change to RAL 7032 by means of a replacement grille.

Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate.

Protection class: E N 60 5 29 I P 5 4 (not suitable for outdoor equipment).

Parameters

Type

Fan Model

Rated Voltage

Speed

Frequency

current

Power

Max Air Flow

Static Pressure

Noise

Curve

external dimensions

V

V

Hz

(A)

(W)+10%-20%

m3/h

(Pa)

(dB)

(mm)

FJK6623PB115

FJ12038PB12

115 AC

75...125

50

0.24

18

102

35

32

204x204x105

60

0.20

15

119

44

35

FJK6623PB230

FJ12038PB24

230 AC

150...250

50

0.12

19

102

35

32

60

0.10

14

119

44

35

FJK6623M230

FJ12032MAB

230 AC

110...250

50

0.12

18

135

65

36

60

0.10

16

150

75

38

FJK6623PB12

FJ12038PB12

12 DC

6...13.8

 

0.55

6.60

126

42

36

 

FJK6623PB24

FJ12038PB24

24 DC

10...27.5

 

0.31

7.44

126

42

36

 

Wide range fan

High efficient air flow , high protection class ,

fast installation , easy connection of power supply

Fast tool-less installation

both insert installation and screw installation type are available

High efficient exhaust design, 50% increase average

Ventilation shutter maximal optimized the air circulation

Easy maintain

Fast filter pad replacement Fast ,

easy and safe filter pad replacement, even during operation

 

Minimized air pressure wastage

Improvement of fan installation distance to filter and

perfect reliable design of air room is verified by study and

test to be better aerodynamics and less air pressure loss.

Thermoduric seal loop

Polyurethane gasket assures long-term seal

Environment

Recycling plastic and filter pad Fan motor according to RoHS

 

Feedback

Related Products

Related News

> Air filter fan manufacturers tell you about the definition and function of fan filters

many people still don’t know what a fan filter is and what its advantages are. The following Air filter fan manufacturers will lead you to have a specific understand...

> Do centrifugal fans generally have a longer life than axial fans? Introduce the characteristics of centrifugal fan and axial fan

Generally, the centrifugal fan has a service life of 3-6 years. The maintenance is basically the replacement of the coil or the maintenance of the circuit after the ...

> The principle of the ancient wooden hulling valley windmill is basically the same as that of the modern centrifugal fan

It has wooden bellows of equal width like the casing of a modern multi-blade centrifugal fan, with a square opening for putting millet on it, a square opening on the...

> Discuss the installation skills and how to choose the cooling fan for the cabinet

The installation of the cooling fan in the cabinet, many people think that it is very easy. Install the cabinet cooling fan wherever there is space in the cabinet. W...

> Introduce the working principle of axial flow fan and the difference from centrifugal fan

What is an axial fan?There are many types of fans, exhaust axial fan is one of them, so what is an exhaust axial fan?An exhaust axial fan, also known as an axial fan...

> The manufacturer of the air filter fan will tell you about the analysis of the fan's air volume

The manufacturer of the air filter fan tells you that the fan capacity is selected according to the maximum air volume required by the process equipment, but the air...

Dialogue with Jasonfan wind turbine solution experts

TelTel:+86-577-55775657