Material of filter pad: 100g/ M3 nylon fiber compound, Filtration efficiency up to 73%.
Operation Temperature/Humidity Range: (under unconcretionary state) -20℃ ~ +65℃ (temperature), 0% ~ 95% (himidity)
RAL 7035 grey is the standard offer with the possibility to change to RAL 7032 by means of a replacement grille.
Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate.
Protection class: E N 60 5 29 I P 5 4 (not suitable for outdoor equipment).
References are based on the frame dimension, which helps you to quickly select the best choice for your installation.
Example:
When your installation space is enough for dimention 120*120*38mm, please choose FJ1203
When you choose AC 220V, frame size 120x120x38mm, sleeve bearing, plug-in connection, please choose model FJ12032AST
We can customize your unconventional products.
Characteristics:
It comprises of a cooling fan, a protective housing on the front and rear surfaces and filter designed to retain dust particles.
The filters that equip the fans must be cleaned and replaced regularly.
It can produce all kinds of flame retardant V0 grade material and filter panel.
Material of filter pad: 100g/ M3 nylon fiber compound, Filtration efficiency up to 73%.
Operation Temperature/Humidity Range: (under unconcretionary state) -20℃ ~ +65℃ (temperature), 0% ~ 95% (himidity)
RAL 7035 grey is the standard offer with the possibility to change to RAL 7032 by means of a replacement grille.
Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate.
Protection class: E N 60 5 29 I P 5 4 (not suitable for outdoor equipment).
Parameters
Type |
Fan Model |
Rated Voltage |
Speed |
Frequency |
current |
Power |
Max Air Flow |
Static Pressure |
Noise |
Curve |
external dimensions |
V |
V |
Hz |
(A) |
(W)+10%-20% |
m3/h |
(Pa) |
(dB) |
(mm) |
|||
FJK6620PB115 |
FJ8021AB |
115 AC |
75...125 |
50 |
0.13 |
13 |
22 |
29 |
28 |
① |
106.5x106.5x52 |
60 |
0.15 |
15 |
26 |
33 |
30 |
||||||
FJK6620PB230 |
FJ8022AB |
230 AC |
150...250 |
50 |
0.07 |
13 |
22 |
29 |
28 |
||
60 |
0.06 |
11 |
26 |
33 |
30 |
||||||
FJK6620M230 |
FJ8032MAB |
230 AC |
150...250 |
50 |
0.09 |
12 |
40 |
33 |
32 |
③ |
|
60 |
0.07 |
10 |
46 |
38 |
32 |
||||||
FJK6620PB12 |
FJ8025PB12 |
12 DC |
7...14 |
|
0.18 |
2.08 |
46 |
30 |
32 |
②
|
|
FJK6620PB24 |
FJ8025PB24 |
24 DC |
12...28 |
|
0.10 |
2.52 |
46 |
30 |
32 |
Wide range fan High efficient air flow , high protection class , fast installation , easy connection of power supply |
Fast tool-less installation both insert installation and screw installation type are available |
High efficient exhaust design, 50% increase average Ventilation shutter maximal optimized the air circulation |
Easy maintain Fast filter pad replacement Fast , easy and safe filter pad replacement, even during operation
|
Minimized air pressure wastage Improvement of fan installation distance to filter and perfect reliable design of air room is verified by study and test to be better aerodynamics and less air pressure loss. |
Thermoduric seal loop Polyurethane gasket assures long-term seal |
Environment Recycling plastic and filter pad Fan motor according to RoHS |
many people still don’t know what a fan filter is and what its advantages are. The following Air filter fan manufacturers will lead you to have a specific understand...
Generally, the centrifugal fan has a service life of 3-6 years. The maintenance is basically the replacement of the coil or the maintenance of the circuit after the ...
It has wooden bellows of equal width like the casing of a modern multi-blade centrifugal fan, with a square opening for putting millet on it, a square opening on the...
The installation of the cooling fan in the cabinet, many people think that it is very easy. Install the cabinet cooling fan wherever there is space in the cabinet. W...
What is an axial fan?There are many types of fans, exhaust axial fan is one of them, so what is an exhaust axial fan?An exhaust axial fan, also known as an axial fan...
The manufacturer of the air filter fan tells you that the fan capacity is selected according to the maximum air volume required by the process equipment, but the air...
Dialogue with Jasonfan wind turbine solution experts
Tel:+86-577-55775657