Motor: Cage type capacitor start external rotor motor
Impeller: Pressed from metal armor plate, impellers are welded to motor rotor and its surface is black and anti-corrosion
Fixed Guard: Steel wire is finished with black paint and anti-corrosion treatment
Allowable environment temperature and humidity range:(under unconcretionary condition) -40℃ ~ +75℃ (temperature) 0% ~ 95% (humidity)
Protection: Automatic recovery thermal protection
Withstand Voltage: AC 1,800V , 1 min at 0.5mA, 50/60 Hz
Insulation Grade: Design according to IEC61858 Grade F,
Protection Grade: Protection Grade IP54
Reference based on the size of impeller, which helps you to quickly select the best choice for your installation
Example:
When you need fan motor 4 poles, input voltage 230V, impeller diameter Ø 350 mm, please choose FJ4E - 350
When you need 4 poles, impeller diameter 350 mm, fan needs basket-type protection guard, airflow direction from motor to guard, Please choose FJ4E - 350. FGV
We can customize your unconventional products.
Motor
Cage type capacitor start external rotor motor
Impeller
Pressed from metal armor plate, impellers are welded to motor rotor and its surface is black and anti-corrosion
Fixed Guard
Steel wire is finished with black paint and anti-corrosion treatment
Allowable environment temperature and humidity range:(under unconcretionary condition)
-40℃ ~ +75℃ (temperature) 0% ~ 95% (humidity)
Protection
Automatic recovery thermal protection
Withstand Voltage
AC 1,800V , 1 min at 0.5mA, 50/60 Hz
Insulation Grade
Design according to IEC61858 Grade F,
Protection Grade
Protection Grade IP54
C2E-250.FG.V
Type |
Motor |
Rated Voltage |
Frequency |
current |
Power |
Speed |
Max Air Flow |
Static Pressure |
Noise |
Curve |
Capacitor Motor |
|
V |
Hz |
(A) |
(W)+10%-20% |
(min-1) |
CFM |
m3/h |
(Pa) |
(dB) |
(μF) |
|||
FJ2S-250.FGV/A |
M2S9202-AF |
115 |
50 |
1.10 |
110 |
2500 |
1080 |
1830 |
150 |
69 |
① |
8.0/250 |
60 |
1.20 |
136 |
2650 |
1151 |
1950 |
150 |
70 |
|||||
FJ2E-250.FGV/A |
M2E9202-AF |
230 |
50 |
0.48 |
105 |
2550 |
1100 |
1867 |
150 |
69 |
② |
3.0/450 |
60 |
0.62 |
140 |
2800 |
1215 |
2060 |
160 |
71 |
|||||
FJ2D-250.FGV/A |
M2D9202-AF |
400 |
50 |
0.29 |
115 |
2550 |
1100 |
1867 |
150 |
69 |
1.0/630 |
|
60 |
0.39 |
150 |
2800 |
1215 |
2060 |
160 |
71 |
|||||
FJ4E-250.FGV/A |
M4E9202-AF |
230 |
50 |
0.24 |
50 |
1400 |
596 |
1010 |
80 |
54 |
③ |
1.5/450 |
60 |
0.25 |
57 |
1650 |
708 |
1200 |
100 |
58 |
FJ2E-250.A
Type |
Motor |
Rated Voltage |
Frequency |
current |
Power |
Speed |
Max Air Flow |
Static Pressure |
Noise |
Curve |
Capacitor Motor |
|
V |
Hz |
(A) |
(W)+10%-20% |
(min-1) |
CFM |
m3/h |
(Pa) |
(dB) |
(μF) |
|||
FJ2S-250.V/A |
M2S9202-AF |
115 |
50 |
1.10 |
110 |
2550 |
1098 |
1860 |
150 |
67 |
① |
8.0/250 |
60 |
1.20 |
140 |
2800 |
1239 |
2100 |
155 |
69 |
|||||
FJ2E-250.V/A |
M2E9202-AF |
230 |
50 |
0.48 |
105 |
2550 |
1098 |
1860 |
150 |
67 |
3.0/450 |
|
60 |
0.62 |
140 |
2800 |
1239 |
2100 |
155 |
69 |
|||||
FJ2D-250.V/A |
M2D9202-AF |
380 |
50 |
0.29 |
115 |
2550 |
1098 |
1860 |
150 |
67 |
1.0/630 |
|
60 |
0.39 |
150 |
2800 |
1239 |
2100 |
155 |
69 |
many people still don’t know what a fan filter is and what its advantages are. The following Air filter fan manufacturers will lead you to have a specific understand...
Generally, the centrifugal fan has a service life of 3-6 years. The maintenance is basically the replacement of the coil or the maintenance of the circuit after the ...
It has wooden bellows of equal width like the casing of a modern multi-blade centrifugal fan, with a square opening for putting millet on it, a square opening on the...
The installation of the cooling fan in the cabinet, many people think that it is very easy. Install the cabinet cooling fan wherever there is space in the cabinet. W...
What is an axial fan?There are many types of fans, exhaust axial fan is one of them, so what is an exhaust axial fan?An exhaust axial fan, also known as an axial fan...
The manufacturer of the air filter fan tells you that the fan capacity is selected according to the maximum air volume required by the process equipment, but the air...
Dialogue with Jasonfan wind turbine solution experts
Tel:+86-577-55775657