C2E-200.FG.V

C2E-200.FG.V

Motor: Cage type capacitor start external rotor motor

ImpellerPressed from metal armor plate, impellers are welded to motor rotor and its surface is black and anti-corrosion

Fixed Guard: Steel wire is finished with black paint and anti-corrosion treatment

Allowable environment temperature and humidity range:(under unconcretionary condition) -40℃ ~ +80℃ (temperature) 0% ~ 95% (humidity)

Protection: Automatic recovery thermal protection

Withstand Voltage: AC 1,800V , 1 min at 0.5mA, 50/60 Hz

Insulation Grade: Design according to IEC61858 Grade F,

Protection Grade: IP54

External Rotor Sickle Impeller C2E-200.FG.V

Technical Parameter

Reference based on the size of impeller, which helps you to quickly select the best choice for your installation

Example:
When you need fan motor 4 poles, input voltage 230V, impeller diameter Ø 350 mm, please choose FJ4E - 350

When you need 4 poles, impeller diameter 350 mm, fan needs basket-type protection guard, airflow direction from motor to guard, Please choose FJ4E - 350. FGV

We can customize your unconventional products.


Motor
Cage type capacitor start external rotor motor

Impeller
Pressed from metal armor plate, impellers are welded to motor rotor and its surface is black and anti-corrosion

Fixed Guard
Steel wire is finished with black paint and anti-corrosion treatment

Allowable environment temperature and humidity range:(under unconcretionary condition)
-40℃ ~ +80℃ (temperature) 0% ~ 95% (humidity)

Protection
Automatic recovery thermal protection

Withstand Voltage
AC 1,800V , 1 min at 0.5mA, 50/60 Hz

Insulation Grade
Design according to IEC61858 Grade F,

Protection Grade
IP54


C2E-200.FG.V

 

 

 

Type

Motor

Rated Voltage

Frequency

current

Power

Speed

Max Air Flow

Static Pressure

Noise

Curve

Capacitor Motor

V

Hz

(A)

(W)+10%-20%

(min-1)

CFM

m3/h

(Pa)

(dB)

(μF)

FJ2S-200.FGV

M2S9201-AF

115

50

0.64

60

2550

525

890

140

64

5.0/250

60

0.62

70

2800

584

990

140

67

FJ2E-200.FGV

M2E9201-AF

230

50

0.29

65

2550

525

890

140

64

1.5/450

60

0.33

75

2800

584

990

140

67

FJ2D-200.FGV

M2D9201-AF

400

50

0.17

61

2550

525

890

140

64

0.5/630

60

0.19

71

2800

584

990

140

67

FJ4S-200.FGV

M4S9201-AF

115

50

0.28

30

1350

274

465

50

42

3.0/250

60

0.28

31

1600

322

545

50

46

 


FJ2E-200.A

 

 

 

Type

Motor

Rated Voltage

Frequency

current

Power

Speed

Max Air Flow

Static Pressure

Noise

Curve

Capacitor Motor

V

Hz

(A)

(W)+10%-20%

(min-1)

CFM

m3/h

(Pa)

(dB)

(μF)

FJ4S-200.A

M4S9201-AF

115

50

0.28

30

1350

289

490

55

41

3.0/250

60

0.28

31

1600

342

580

60

45

FJ2E-200.A

M2E9201-AF

230

50

0.29

65

2500

535

906

90

58

1.5/450

60

0.33

75

2700

578

979

115

60

FJ2D-200.A

M2D9201-AF

380

50

0.17

61

2550

546

925

100

59

0.5/630

60

0.19

71

2800

599

1015

120

61


FJ2E-200.TSV

 

 

 

Type

Motor

Rated Voltage

Frequency

current

Power

Speed

Max Air Flow

Static Pressure

Noise

Curve

Capacitor Motor

V

Hz

(A)

(W)+10%-20%

(min-1)

CFM

m3/h

(Pa)

(dB)

(μF)

FJ2E-200.TSV

M2S9201-TS

230

50

0.20

43

2000

480

810

85

57

2.0/450

50

0.19

38

1750

415

705

75

53

50

0.16

32

1350

321

545

50

49

Feedback

Related Products

Related News

> Air filter fan manufacturers tell you about the definition and function of fan filters

many people still don’t know what a fan filter is and what its advantages are. The following Air filter fan manufacturers will lead you to have a specific understand...

> Do centrifugal fans generally have a longer life than axial fans? Introduce the characteristics of centrifugal fan and axial fan

Generally, the centrifugal fan has a service life of 3-6 years. The maintenance is basically the replacement of the coil or the maintenance of the circuit after the ...

> The principle of the ancient wooden hulling valley windmill is basically the same as that of the modern centrifugal fan

It has wooden bellows of equal width like the casing of a modern multi-blade centrifugal fan, with a square opening for putting millet on it, a square opening on the...

> Discuss the installation skills and how to choose the cooling fan for the cabinet

The installation of the cooling fan in the cabinet, many people think that it is very easy. Install the cabinet cooling fan wherever there is space in the cabinet. W...

> Introduce the working principle of axial flow fan and the difference from centrifugal fan

What is an axial fan?There are many types of fans, exhaust axial fan is one of them, so what is an exhaust axial fan?An exhaust axial fan, also known as an axial fan...

> The manufacturer of the air filter fan will tell you about the analysis of the fan's air volume

The manufacturer of the air filter fan tells you that the fan capacity is selected according to the maximum air volume required by the process equipment, but the air...

Dialogue with Jasonfan wind turbine solution experts

TelTel:+86-577-55775657