C2E-225.63C

Motor: Cage type capacitor structure external rotor motor

Impeller: Black PA nylon one-time injection moulding

Allowable environment temperature and humidity range:(under unconcretionary condition) -40 ~ +80 (temperature) 0% ~ 95% (humidity)

Protection: Motor Internal with automatic recovery thermal protector

Withstand Voltage: AC 1,800V , 1 min at 0.5mA, 50/60 Hz

Insulation Grade: design according to IEC61858 Grade F

Protection Grade: IP44

Centrifugal Fan C2E-225.63C

Technical Parameter

Reference based on the shape and size of outlet, which helps you to quickly select the best choice for your installation.

Example: If your spin room fitted to impeller diameter Ø 225 mm, outlet size 63 mm, voltage 230V, 2 poles motor, please choose model FJC2E22563

When you look for centrifugal fan of dual voltage 230 V / 400 V, 4 poles motor, spin room fitted to impeller diameter Ø 225 mm, please choose model FJC4ED225

We can customize your unconventional products.


Motor
Cage type capacitor structure external rotor motor

Impeller
Black PA nylon one-time injection moulding

Allowable environment temperature and humidity range:(under unconcretionary condition)
 -40 ~ +80 (temperature) 0% ~ 95% (humidity)

Protection
Motor Internal with automatic recovery thermal protector

Withstand Voltage
AC 1,800V , 1 min at 0.5mA, 50/60 Hz

Insulation Grade
design according to IEC61858 Grade F

Protection Grade
IP44


C2E-225.63C

 

 

 

Type

Motor

Rated Voltage

Frequency

current

Power

Speed

Max Air Flow

Static Pressure

Noise

Curve

Capacitor Motor

V

Hz

(A)

(W)+10%-20%

(min-1)

CFM

m3/h

(Pa)

(dB)

(μF)

C2S-225.63C

M2S9203-AF

115

50

1.25

119

2650

708

1200

540

68

10.0/250

60

1.37

152

2950

790

1340

730

71

C2E-225.63C

M2E9203-AF

230

50

0.60

131

2650

708

1200

540

68

4.0/450

60

0.74

170

2950

790

1340

730

71

C2D-225.63C

M2D9203-AF

380

50

0.33

125

2650

708

1200

540

68

2.0/630

60

0.48

180

2950

790

1340

730

71

C4E-225.63C

M4E9203-AF

230

50

0.28

51

1390

371

629

290

54

1.5/450

60

0.24

53

1640

437

742

400

60

 


C2E-225.63DS

 

 

 

Type

Motor

Rated Voltage

Frequency

current

Power

Speed

Max Air Flow

Static Pressure

Noise

Curve

Capacitor Motor

V

Hz

(A)

(W)+10%-20%

(min-1)

CFM

m3/h

(Pa)

(dB)

(μF)

C2E-225.63DS

M2E9203-DS

240

50

0.38

92

2380

635

1077

485

66

3.0/450

50

0.37

86

2220

593

1005

452

64

 

Feedback

Related Products

Related News

> Air filter fan manufacturers tell you about the definition and function of fan filters

many people still don’t know what a fan filter is and what its advantages are. The following Air filter fan manufacturers will lead you to have a specific understand...

> Do centrifugal fans generally have a longer life than axial fans? Introduce the characteristics of centrifugal fan and axial fan

Generally, the centrifugal fan has a service life of 3-6 years. The maintenance is basically the replacement of the coil or the maintenance of the circuit after the ...

> Why is the centrifugal fan better than the ordinary fan?-Jason takes you to solve the problem

Fans are widely used in our production work. As a professional manufacturer of centrifugal fans, Jason Fan Manufacturing, let me tell you what are the advantages of ...

> The principle of the ancient wooden hulling valley windmill is basically the same as that of the modern centrifugal fan

It has wooden bellows of equal width like the casing of a modern multi-blade centrifugal fan, with a square opening for putting millet on it, a square opening on the...

> Discuss the installation skills and how to choose the cooling fan for the cabinet

The installation of the cooling fan in the cabinet, many people think that it is very easy. Install the cabinet cooling fan wherever there is space in the cabinet. W...

> Introduce the working principle of axial flow fan and the difference from centrifugal fan

What is an axial fan?There are many types of fans, exhaust axial fan is one of them, so what is an exhaust axial fan?An exhaust axial fan, also known as an axial fan...

Dialogue with Jasonfan wind turbine solution experts

TelTel:+86-577-55775657